CyBi Felix

CYBI
FELIX

Fully Automated Liquid Handling System

CyBi®-FeliX represents a new wave of flexibility liquid handling not seen in automated liquid handling platforms.  The CyBi®-FeliX has 12 deck positions on two levels for microplates, tube racks, reservoirs and tips on the small footprint of 650 x 450 mm.  Precise pipetting for your liquid handling tasks within the volume range of 0.5 μl – 1000 μl.  Full format flexibility with automatic loading of liquid handling adapters and tips and is compatible with Universal Pipette Tip e.g. Axygen Pipette Tips

Make an Enquiry

Fully Automated, Ultra Compact Liquid Handling System

The CyBi®-FeliX CHOICE™ is a flexible and compact liquid handling platform for the processing of tubes, single wells, rows and columns in different plate formats with highest volume flexibility. The system has 12 deck positions on two levels for microplates, tube racks, reservoirs and tips on the small footprint of 650 x 450 mm (w x d).

The platform achieves a unique volume range of 0.5 μl – 1000 μl with only one pipetting head based on the patent pending CHOICE™ technology. The different CHOICE™ adapters with built-in tip loading are picked up by the pipetting head automatically and allow 1, 8, 12 and 16 channel pipetting without the need of manual intervention. This allows the CyBi®-FeliX CHOICE™ to work in different volume ranges, plate formats and in tubes.

96 and 384 Channel Compatibility

For highest precision in every volume range, there are the interchangeable pipetting heads 96/250 µl as well as 384/60 µl with the proven tip sealing technology available. Along with the parallel processing of whole 96- and 384-well microplates, the different liquid handling adapters also allow work in single wells, rows and columns. The pickup of liquid handling adapters and tips is performed by the pipetting head without the need of manual intervention. After the pickup, each adapter is identified with optimised pipetting parameters and correct volume range set for the highest pipetting precision possible.

The CyBi®-FeliX CHOICE™ can also be upgraded with 96 and 384 channel pipetting heads at any time following the initial installation.  The platform can be adjusted to any application requirements through the right combination of pipetting heads, accessories and tips.

Composer Software

CyBi®-FeliX Composer Software enables users to set up assays in minutes.  Intuitive workflow editor, integrated drag & drop support and reagent tracking via colour-coding makes the FeliX researcher friendly.

Key Features

  • Flexible: 1 – 384 channel pipetting without the need for manual exchanges
  • Compatible: Compatible with limitless range of labware including 1536 well plates
  • Volume Range: 0.5 μl – 1000 μl volume range with no user intervention
  • Compact: 12 positions deck (650 x 650 x 450 mm) – Fits inside any laminar flow and/or biohazard cabinet
  • Superior Design: Excellent precision and accuracy specifications
  • Each To Use: Research- Friendly, workflow based software
  • Wide Range of Accessories: Tip Wash, UV w/HEPA Filter, Plate Carrier, Heater/Shaker etc…

Product Range

Cat. No.

Description
30-5015-125-20

CyBi®-FeliX 8-Channel Workstation Includes CyBi®-FeliX Basic Unit, CHOICE™ Head and one 8-Channel CHOICE™ Adapter

30-5015-100-24

CyBi®-FeliX Basic Unit

OL3316-14-250

CHOICE™ Head

OL3316-14-850

CyBi®-FeliX Head R 96/250 µl

OL3316-14-555

CyBi®-FeliX Head T 384/60 µl

OL3316-14-855

CyBi®-FeliX Head T 96/250 µl

OL3316-11-350 1-Channel CHOICE™ Adapter
OL3316-11-330 8-Channel CHOICE™ Adapter
OL3316-11-340 12-Channel CHOICE™ Adapter
OL3316-11-380 16-Channel CHOICE™ Adapter
   
CyBi Felix Accessories
Cat. No. Description:
8037108-00 Bioshake 3000 T-ELM Shaker with temperature unit
OL3396-262-24 Heating adapter PCR only for 96 well PCR plates, stripes also possible; heating adapter temperature controller OL3396-266-24 necessary
OL3396-259-24 Heating adapter flat bottom for reservoirs and 96 well flat bottom plates; heating adapter temperature controller OL3396-266-24 necessary
OL3396-272-24 Heating adapter round bottom for 96 well round bottom plates, designed for half DW plate (30-7021-150-25); heating adapter temperature controller OL3396-266-24 necessary
OL3396-266-24 Heating adapter temperature controller for running different types of heating adapters
844-00136-0 Tube Rack for 24 tubes with or without lid from 1.5 up to 2 ml, only usable in combination with standard adapter
844-00137-0 Tube rack; mixed for 24 tubes, 8x 1.5/ 2 ml tubes, 8x 0.5 ml tubes and 8x 0.2 ml PCR tubes, only usable in combination with standard adapter
OL0051-20-951 PCR Cooler SBS format for automated processing; for 0.2 ml PCR tubes and stripes as well as 96 well PCR plates, only usable in combination with standard adapter
OL3397-25-820 PCR plate adapter adapter for all types of PCR plates, standardized plate bottom height; adapter and/or plates not stackable!
OL3397-25-822 Magnetic adapter for 96-well plates with U- or V-bottom, 24 magnets (1 per 4 wells)
OL0026-345-24 Tip wash station module, incl tip wash trough and 2 pumps

 

PRODUCT ENQUIRY